New build residential
Fire strategies for new houses and blocks of flats at planning and Building Control stage, including single stair justification and the second staircase provisions in force from 30 September 2026.
Independent fire safety consultancy for landlords, managing agents, developers and design teams. Clear, defensible documents that satisfy Building Control and the Fire Authority without over-engineering the cost.
Working across the United Kingdom, the UAE and Saudi Arabia.
Fire risk assessment
If you are the responsible person for a building, the law requires a suitable and sufficient fire risk assessment, recorded in full and kept under review. We assess single buildings and whole portfolios to PAS 79-1:2020 for non-housing premises and BS 9792:2025 for housing, with a prioritised, plain-English action plan.
Government guidance for purpose-built blocks of flats sets out four types of fire risk assessment, defined by how far the inspection goes and whether construction is opened up. The right type controls both the cost and what the assessment can tell you.
The basic assessment required to satisfy the Fire Safety Order, and normally sufficient for most purpose-built blocks unless there is reason to expect serious deficiencies.
Types 2 and 4 open up construction on a sampling basis, usually with a contractor to make good, and are only appropriate where there is good reason.
Types 3 and 4 extend into a sample of flats, beyond the scope of the Fire Safety Order. They are not normally possible in long leasehold flats, where the freeholder usually has no right of access.
Not sure which type you need? Send us the address, height and number of flats, with the date of the last assessment. We will recommend the right type and confirm a fixed fee.
Request a fire risk assessment quoteType 1: common parts only, non-destructive. The basic assessment required to satisfy the Fire Safety Order. We inspect the common parts and a sample of flat entrance doors, lifting ceiling tiles and opening service risers on a sample basis where practicable. Flats are not entered beyond the entrance door.
Type 2: common parts only, destructive. As Type 1, with construction opened up on a sampling basis, usually by a contractor who makes good afterwards. Usually a one-off, carried out only where there is good reason to suspect serious structural deficiencies that could let fire spread. The age of a block alone is not generally enough.
Type 3: common parts and flats, non-destructive. As Type 1, plus means of escape and fire detection within a sample of flats. This goes beyond the Fire Safety Order, and can suit rented flats where there is reason to suspect serious risk to residents from a fire in their own flat.
Type 4: common parts and flats, destructive. As Type 3, with opening up on a sampling basis in both the common parts and the flats, often only in vacant flats. The most comprehensive assessment, appropriate only in limited circumstances, such as a new landlord taking on a block where the history of works is unknown.
Schematic section, not to scale. Types as set out in the government guide Fire safety in purpose-built blocks of flats, which is being revised.
The government's fire risk assessment guides, published under Article 50 of the Fire Safety Order and now overseen by the Ministry of Housing, Communities and Local Government, together with the LACORS guide for existing housing, including HMOs.
Every assessment is led by an assessor on the National Fire Risk Assessor Register at Advanced Level, and backed by professional indemnity and public liability insurance.
Verify on the NFRAR registerFire strategy
Building Control and the Fire Authority will ask for a fire strategy. We produce it for you: a clear document that sets out means of escape, compartmentation, fire alarm provision, external fire spread and fire service access for your specific building.
Fire strategies for new houses and blocks of flats at planning and Building Control stage, including single stair justification and the second staircase provisions in force from 30 September 2026.
Change of use from offices, shops or banks to residential is where fire strategy matters most: the existing building was never designed for sleeping risk. We have delivered these from Victorian bank conversions to Class E to C3 schemes.
Flats above commercial units, extensions, and alterations to existing commercial buildings, with the separation and escape provisions Building Control will expect to see.
Splitting a house or commercial building into flats brings compartmentation, alarm and escape requirements most builders underestimate. We resolve them at design stage, before they cost you money on site.
Converting a house to an HMO? We set out the escape routes, fire doors, detection and protection your licence and Building Control approval depend on.
Existing buildings with no fire strategy on record, buildings under enforcement, prohibition notices or Fire Authority scrutiny. We produce the retrospective strategy that regularises your position.
Discuss an existing buildingExperience also includes complex higher-risk residential buildings, heritage and listed properties, places of worship and mixed-use developments.
Now in force in England
The second staircase amendments now apply. If your scheme includes a block of flats with a storey 18 m or more above ground level, this is what changes and where your scheme stands.
New blocks of flats with a storey 18 m or more above ground level need more than one common stair. Height is measured from ground level to the floor of the top storey, excluding roof-top plant.
Common stairs in these blocks need a clear width of at least 1,100 mm between walls or balustrades.
Where an evacuation lift is provided, the guidance now sets out its evacuation shaft, protected lobby, access and smoke protection.
Not sure which edition applies to your scheme? Send the drawings with your Building Control application type and date, and we will confirm where you stand before you commit to a design.
Check my schemeUntil 29 September 2026. A single common stair could serve a block of flats of this height, subject to the travel distance, protection and smoke ventilation limits in Approved Document B.
From 30 September 2026. More than one common stair, each at least 1,100 mm clear. Where an evacuation lift is provided, it needs an evacuation shaft, a protected lobby and smoke protection to the new guidance.
Proposed. The Building Safety Regulator's review of Approved Document B proposes recommending evacuation lifts in residential buildings above 18 m. This is not yet in force: the consultation closed on 1 July 2026 and the outcome is awaited.
Schematic section, not to scale. Firefighting shaft and other provisions not shown.
The previous guidance can still apply to a scheme that passes both tests below.
A building notice, initial notice or full plans application. Planning permission on its own does not count.
For new build, concrete poured for permanent foundations or permanent piling started. For existing buildings, the work has started.
On higher-risk buildings nothing can start on site until the Building Safety Regulator grants Gateway 2 approval, so the window is tighter than it looks.
Sprinklers in new care homes, European classifications for reaction to fire and roofs, and updated Regulation 38 fire safety information.
The Building Safety Regulator's review proposes recommending evacuation lifts above 18 m, with changes for external walls, balconies and solar PV on roofs.
BS 476 national classes for fire resistance are withdrawn. Product specifications will need European classifications.
We work to Approved Document B, 2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, collated with the 2029 amendments, together with BS 9991:2024 and BS 9999:2017, and will tell you exactly where your scheme stands.
Read the guidance on GOV.UKEvery instruction is led by a qualified, registered fire professional and reviewed at director level before it is issued.
Our core service. Tailored fire strategies for new build projects at planning stage and retrospective strategies for existing buildings, written to the latest Approved Document B and, where the project calls for it, BS 9991:2024 and BS 9999:2017. Each strategy covers everything Building Control and the Fire Authority will scrutinise:
Expert navigation of Approved Document B, BS 9991, BS 9999 and associated standards for Building Control and Fire Service submissions, including Building Safety Act advisory work on higher-risk buildings and consultation responses.
Performance-based fire engineering solutions delivering innovative, cost-effective outcomes without compromising life safety standards, including evacuation analysis and smoke control appraisal.
Comprehensive assessments for commercial and residential properties under the Regulatory Reform (Fire Safety) Order 2005, following PAS 79-1:2020 for non-housing premises and BS 9792:2025 for housing, with a prioritised, plain-English action plan.
Fire risk assessment in detailSupport with enforcement notices, prohibition notices and Fire Authority consultation, including waking watch review, fire alarm justification to BS 5839-1:2025 and BS 5839-6, and technical responses that protect your position.
Compartmentation surveys, external wall fire risk appraisals to PAS 9980:2022 and EWS1 assessments for existing residential buildings, with remediation advice that is proportionate to the risk.
Advisory work to the UAE Fire and Life Safety Code of Practice and the Saudi Building Code, SBC 801, for developers and consultants delivering projects across the region.
A single point of contact from first enquiry to final report, with the right specialists on every job.
Fire risk assessment
Address, use, height and number of storeys, number of flats or units, and the date of the last assessment.
The right type of assessment agreed up front, with a fixed fee and insurance certificates on request.
A thorough inspection of the premises. In blocks of flats, the common parts and a sample of flat entrance doors, going into flats or opening up only where agreed.
The assessment recorded in full with the assessor named, and actions prioritised in plain English.
Help closing out actions, liaison with the fire and rescue service where needed, and a review date that keeps the assessment current.
Fire strategy
Plans, sections and elevations, with the planning status and your Building Control route.
A clear scope and a fixed fee before any work starts, with insurance certificates on request.
Escape, compartmentation and access issues resolved at design stage, before they reach site and cost you money.
A Building Control ready strategy written for your specific building, not a template.
Responses to Building Control and fire service comments until the strategy is agreed. The strategy then forms part of the Regulation 38 fire safety information at completion.
“We empower businesses with proactive risk management strategies, helping protect what matters most: lives, property, and peace of mind.”
Our team is led by a director with hands-on experience from a major UK Fire & Rescue Service and the private sector as a specialist fire safety advisor. We elevate fire safety standards through innovative approaches and collaborative partnerships, with a firm belief that an investment in knowledge yields the greatest returns.
Muz IqbalDirector and Principal Consultant, Faris Fire Solutions Ltd, founded 2019
£5M+
Saved for clients in remediation works through expert fire engineering and strategic compliance guidance.
20+
Years of fire safety experience behind every project, including hands-on service with a major UK Fire & Rescue Service.
3
Regulatory regimes covered: UK, UAE and Saudi Arabia, for developers and operators working across borders.
Member grade, MIFireE
Fellow, FIFSM
Professional indemnity and public liability insurance in place. Certificates available on request.
Fire safety codes differ by jurisdiction, and applying the wrong one is an expensive mistake. We work across three regulatory regimes and advise clients building or operating in each.
Approved Document B, BS 9991:2024, BS 9999:2017
Fire strategies, risk assessments and Building Regulations guidance to Approved Document B and British Standards, with established working relationships with Building Control bodies and Fire & Rescue Services nationwide.
UAE Fire and Life Safety Code of Practice
Advisory work aligned to the UAE Fire and Life Safety Code of Practice and Civil Defence requirements, supporting developers and consultants delivering projects across the Emirates.
Saudi Building Code 2024, SBC 801
Fire protection advisory aligned to the Saudi Building Code, SBC 801, in its 2024 edition in force since 30 June 2025, supporting giga-project supply chains and organisations bringing international fire safety expertise into the Kingdom.
Send over your building details or drawings and we will come back to you with a clear, fixed-fee proposal. Early advice costs a fraction of fixing fire safety problems later.
Protecting lives, property and peace of mind
Request a fee proposalThe more of this you can share, the sharper the proposal.